About Us Our Work Employment News & Events
MITRE Remote Access for MITRE Staff and Partners Site Map
Our Work

Follow Us:

Visit MITRE on Facebook
Visit MITRE on Twitter
Visit MITRE on Linkedin
Visit MITRE on YouTube
View MITRE's RSS Feeds
View MITRE's Mobile Apps
Home > Our Work > Technical Papers >

Availability of GAST D GBAS Considering Continuity of Airborne Monitors

March 2010

Curtis A. Shively, The MITRE Corporation
Thomas T. Hsiao, The MITRE Corporation

ABSTRACT

Standards are being developed for using a ground based augmentation system (GBAS) to provide guidance for CAT III approach and landing operations, known as GBAS Approach Service Type D (GAST D). To evolve from CAT I (GAST C) to GAST D an additional method for mitigating potential errors due to ionospheric anomalies must be implemented in the aircraft. This paper considers the continuity risk from monitors and protection levels affected by this additional ionospheric anomaly mitigation. Three such processes are analyzed: 1) dual smoothing ionospheric gradient monitoring algorithm (DSIGMA) monitor, 2) fault-free vertical protection level (VPLH0) and 3) reference receiver fault monitor (RRFM). A geometry constraint needed to independently ensure acceptable continuity risk for each process is first identified. The constraint needed for RRFM has already been included in specifications. However, only geometry constraints needed for adequate integrity protection with DSIGMA have been specified. Thus, the analysis assesses whether continuity constraints for DSIGMA and VPLH0 must also be implemented. The analysis determines the continuity risk from enforcing all or only some of these constraints. Results show that the VPLH0 continuity risk predominates and a corresponding constraint is needed. However, given only the constraint for VPLH0 the continuity risk from DSIGMA could arguably be acceptable. Moreover, even if all constraints are enforced availability of adequate satellite geometry is no less than that limited by the separate geometry constraints needed for proper integrity protection with DSIGMA.

View/Download Document

Additional Search Keywords

n/a

 

Page last updated: April 7, 2010   |   Top of page

Homeland Security Center Center for Enterprise Modernization Command, Control, Communications and Intelligence Center Center for Advanced Aviation System Development

 
 
 

Solutions That Make a Difference.®
Copyright © 1997-2013, The MITRE Corporation. All rights reserved.
MITRE is a registered trademark of The MITRE Corporation.
Material on this site may be copied and distributed with permission only.

IDG's Computerworld Names MITRE a "Best Place to Work in IT" for Eighth Straight Year The Boston Globe Ranks MITRE Number 6 Top Place to Work Fast Company Names MITRE One of the "World's 50 Most Innovative Companies"
 

Privacy Policy | Contact Us